These timers are used for cleaning the bag filters by passing air in the bag filters for a very short time (pulse)
This is done in a sequential manner to clean all bag filters in a cyclic fashion
The number of bag filters decides the stage / channel of timer
The solenoid valves can be energized with the help of electromagnetic relays or through solid state relays
Both the ON time and INTERVAL time (between two stages) are adjustable from the front panel
LEDs are provided to indicate energisation of each solenoid stage and the interval time is indicated by the clock LED
128 clock LED ON / OFF cycles completes the interval time enabling the user to set the interval time accurately
Since the environment around the unit is dusty, the unit is housed in a double enclosure suitable for wall mounting
Applications:
Bag Filters
Specifications:
Nominal Voltage – 240 V ˜± 10% 50 Hz(other voltages are available on request)
No of stagese – 2 to 8 stages
On time – Adjustable 0.1 to 1 sec max through potentiometer on front, Other timings can be provided
Interval time – Adjustable 1 min to 15 min max through potentiometer on front
Indications – LED indication for Each Stage, Power On, Interval Time
Dimensions – W : 96 mm X H : 192 mm X D : 160 mm Wall & Flush mounting
Controls – Power switch, Fuse, “ON” & “INTERVAL” potentiometer
Output contacts – Potential free 240 V-, 5A resistive, Solid state relays can be offered as an option, please specify the solenoid voltage & current before ordering